INPUT MODULES |
Number |
Voltage |
Connection |
16 |
12 – 24VDC |
Terminal
screws |
32 |
12 – 24VDC |
Ribbon
connectors |
32 |
5VDC |
Ribbon
connectors |
64 |
12 – 24VDC |
Ribbon
connectors |
64 |
5VDC |
Ribbon
connectors |
8 Interrupt |
12 – 24VDC |
Terminal
screws |
|
|
|
|
OUTPUT MODULES |
Number
|
Type
|
Rating
|
Voltage
|
Connection
|
16
|
Relay
|
2A
|
250VAC
|
Terminal
screws
|
16
|
Transistor
|
0.5A
|
12 – 24VDC
|
Terminal
screws
|
32
|
Transistor
|
0.1A
|
5 – 24VDC
|
Ribbon
connectors
|
64
|
Transistor
|
0.1A
|
5 – 24VDC
|
Ribbon
connectors
|
|
|
|
|
ANALOGUE INPUT MODULES |
Inputs |
|
Resolution |
12/13 Bit |
|
13 Bit |
Conversion time |
min. 2.5ms |
A/D converter
modules:
Mean-value formation up to 4,000 values selectable. Limit
notification. Offset point and scaling adjustable. |
|
|
|
|
ANALOGUE OUTPUT MODULES |
Inputs |
|
Resolution |
12/13 Bit |
|
13 Bit |
Conversion time |
min. 4ms |
D/A-converter
modules:
Automatic examination of CPU digital signals with definable limit
values. Outputs electrically isolated.
|
|
|
|
|
|
FP3/ FP10SH – Special Intelligent Modules.
|
|
|
|
PT100 MODULE |
The PT100 module with four
inputs offers connections for temperature-dependent resistors
PT100.
|
Temperature
range: -100°C to +200°C
|
|
|
THERMOCOUPLE
MODULE |
The
thermocouple module has four inputs and recognises temperature-dependent
voltages from connected thermocouples.
|
Temperature
range: 0°C to 1,000°C |
|
|
|
|
COMMUNICATIONS MODULES (POINT TO POINT) |
RS232C
module:
Connection of two peripherals Transmission rate: 300 to 19,200
baud.
Computer
communication module:
For ”direct“ communication with the computer. All automation
tasks are controlled or displayed from the computer. The PLC acts
as the slave.
BASIC-module:
Programming in BASIC. Stand-alone data processing. Relieves the
load on the PLC-CPU. Programming via RS232C interface. Multi-tasking.
|
|
|
|
|
MULTI DROP NETWORKS |
MB Link
module:
The entire FP3/10SH series has access to the standardised MODBUS
via the MB LINK module. At data transmission rates of 0.3 to
38.4Kbps and with a maximum of 247 slave stations, process data
can be exchanged extremely rapidly.
C-NET
module:
Slave coupling unit for low-cost incorporation of up to 32
stations via RS485. The communications master is integrated
directly via two-wire circuitry or a C-NET adapter.
|
|
|
|
|
DECENTRALISED I/Os |
MEWNET-TR
Transmitter Master module:
Several master modules can each control up to 256 digital I/Os (32
stations). The number of masters, and therefore the number of
individual networks, is restricted only by the total I/Os of the
FP3 controller available. A primary prerequisite for sensor/actuator
networking in field applications is to save equipment count and
cost.
MEWNET-TR.
Decentralised I/O terminals:
Up to 32 terminal blocks connected actuators and sensors with the
transmitter master module in a space-saving way using two-wire
circuitry (RS485). 4-way, 8-way and 16-way terminal blocks can be
combined in a variety of configurations.
MEWNET-F
Master coupling module:
Up to four master coupling modules can be connected to an
FP3/10SH. Each of the master modules can activate 32 decentralised
slave I/O stations – all via a simple two-wire circuit. That
means cost savings and more flexible automation.
MEWNET-F
Decentralised slave I/O stations:
Actuators, sensors and various ”intelligences“ are linked to
the master modules via decentralised FP slave stations with space-saving
two-wire circuitry.
MEWNET-F
FP3/10SH Slave coupling module:
For, amongst other applications, time-saving ”in situ“
programming of the central MEWNET-F master. The programming system
is connected to the integral RS422 interface of the decentralised
FP3 slave station, thereby offering the FP programmer access to
all system components of the master CPU.
|
|
|
|
|
MULTI-MASTER NETWORKS |
MEWNET-W
coupling module:
The more cost-effective alternative to MEWNET-P is MEWNET-W. Up to
32 FP controllers communicate with one another via a two-wire bus,
whereby every controller in the token bus structure can control
data exchange at various times.
MEWNET-P
coupling module:
This enables up to 63 FP3/10SH controllers to be linked to one
module via fibre optic cables. Over max. 10km distance, two
parallel optic fibres ensure optimum data security in the network
loop.
|
|
|
|
|
NAIS PROFIBUS MODULES |
FMS/DP
master module
permits simultaneous operation of PROFIBUS FMS and DP. This
combined master unit operates of up to 12Mbaud.
DP master
module
allows the FP3/10SH PLC to communicate with and control the slave
devices in the PROFIBUS network up to 12Mbaud.
|
|
|
|
|
FP3-ETHERNET-MODULE |
ET-LAN coupling
module:
The ET-LAN coupling module from Matsushita rounds off the MEWNET
family with standard Ethernet (10base5) at a maximum transmission
rate of 10Mbps upload. |
|
|
|
|
HIGH SPEED COUNTER
AND POSITIONING MODULES |
High
speed counter modules:
They process 1 or 2 phase pulses up to 100kHz in one or two
channels, irrespective of cycle time.
Positioning
modules:
For system-integrated 1 and 2-axis path control. With a starting
frequency of up to 400kHz, this yields a speed of 4,000mm/s. The
resolution is 0.01mm per pulse.
A low-priced
alternative: the AFP 3480 pulse output module.
|
|
|
|